Enterprise network design, without the enterprise procurement cycle.
Multi-site commercial operations and industrial facilities across the Inland Empire, LA, and Orange County need infrastructure built to the same standard as a large enterprise — just without the twelve-month vendor process.
IT and operational systems sharing a network they were never designed to share.
Building automation, access control, cameras, and industrial control or monitoring systems are increasingly connected to the same network as office IT — often without the segmentation that would keep a compromise on one side from reaching the other.
- Site-to-site connectivity for multi-location operations
- Centralized DNS, DHCP & IP address management (DDI) across every site
- Segmentation between office IT and operational/industrial systems, aligned to IEC 62443
- Structured cabling, wireless, and switching design for facilities
- Vendor and third-party access controlled and monitored
- Standardized security posture across every site
- CMMC/DFARS familiarity for defense-adjacent subcontractors
The same discipline used on enterprise systems, applied to your sites.
Multi-Site Architecture
Consistent, documented network design across every location — so site #4 isn't a different security posture than site #1.
IT / OT Separation
Operational and building systems isolated from office IT, aligned to IEC 62443 industrial security practices — reducing the blast radius of any single compromise.
Infrastructure Deployment
Structured cabling, switching, and wireless design and installation for new builds, remodels, and expansions.
Palo Alto, Zscaler, Arista & VMware
Next-gen firewalls and cloud security (Palo Alto, Zscaler), enterprise switching fabric (Arista, Extreme), and virtualized/hyperconverged infrastructure (Cisco HyperFlex, VMware).
Building & Physical Systems Security
Cameras, access control, and building automation systems brought onto a properly segmented network — instead of sitting on the same flat network as everything else.
24/7 Monitoring & Incident Response
Continuous monitoring across every site, with a defined incident response plan so a security event at one location doesn't become a company-wide one.
Frameworks we design and build within.
Hover over any framework to see what it actually requires, who it applies to, and where to read the source policy in full.
Industrial Control Systems & OT Security
- International standard series for cybersecurity of industrial automation and control systems (IACS)
- Developed jointly by ISA (International Society of Automation) and IEC
- Introduces a 'zones and conduits' model for segmenting OT networks into trust boundaries
- Defines Security Levels (SL 1–4) scaled to the sophistication of threat an asset must resist
- Applies across the full lifecycle: asset owners, system integrators, and equipment manufacturers
- Increasingly referenced by insurers and OT vendors as the de facto industrial security benchmark
- Applies to manufacturing, utilities, building automation, and any facility running industrial control systems
- Renamed from 'ICS Security' to 'OT Security' in Revision 3 to cover building automation, transportation, and physical access control systems
- Tailors traditional IT security controls (from NIST SP 800-53) to OT's unique safety and availability constraints
- Prioritizes maintaining safe operation over immediate isolation during incident response
- Explicitly maps to and complements IEC 62443 rather than competing with it
- Recommends consequence-based risk management — physical safety impact, not just data confidentiality
- Treats IT/OT convergence as a primary attack surface requiring dedicated controls
- Applies to any organization operating ICS, SCADA, DCS, or PLCs, especially under federal or critical-infrastructure oversight
Critical Infrastructure
- Mandatory (not voluntary) cybersecurity standards for the North American Bulk Electric System
- 13 active standards, CIP-002 through CIP-015, covering identification, access, monitoring, and recovery
- Enforced by FERC, with penalties reaching $1 million per violation per day
- Requires categorizing cyber systems as high, medium, or low impact under CIP-002
- 2026 updates (CIP-003-9, CIP-012-2) expanded supply-chain and vendor remote-access requirements, even for low-impact assets
- Requires physical access controls, escorted visitor access, and continuous monitoring for covered facilities
- Applies to transmission owners/operators, generator owners/operators, and other registered Bulk Electric System entities
Defense & Export-Controlled Manufacturing
- Three certification levels (1–3) scaled to the sensitivity of data handled
- Level 1: basic safeguarding of Federal Contract Information (FCI), self-assessed
- Level 2: protects Controlled Unclassified Information (CUI), built on NIST SP 800-171
- Phase 2 begins November 10, 2026 — third-party (C3PAO) Level 2 certification becomes standard
- Prime contractors are legally responsible for subcontractor compliance ('flow-down')
- Non-compliant contractors become ineligible for award on applicable DoD solicitations
- Applies to any defense contractor or subcontractor handling FCI or CUI
- NIST SP 800-171 is the control baseline; DFARS 252.204-7012 is the contract clause that legally requires it
- Applies to any DoD contractor or subcontractor system handling Controlled Unclassified Information (CUI)
- Requires reporting a cyber incident to DoD within 72 hours of discovery
- Self-assessment score (-203 to +110) must be current in the DoD's SPRS system
- Flows down contractually to subcontractors regardless of tier
- Increasingly cross-referenced with CMMC Level 2 certification requirements
- Common across Southern California's aerospace and defense subcontractor base
- ITAR (State Department) controls export of defense articles, services, and related technical data
- EAR (Commerce Department) controls dual-use and commercial items with potential military application
- Technical data protection extends directly to how engineering files and drawings are stored and transmitted
- A 'deemed export' can occur simply by giving a foreign national employee access to controlled data
- Violations carry severe civil and criminal penalties, including debarment from government contracting
- Often requires a Technology Control Plan (TCP) for facilities and IT systems handling controlled data
- Common in Southern California's aerospace, defense, and dual-use manufacturing corridor
General Information Security
- Organizes cybersecurity activity into six functions: Govern, Identify, Protect, Detect, Respond, Recover
- Voluntary but widely adopted as the common risk-management vocabulary across industry
- Serves as the reference model that IEC 62443, NIST SP 800-82, and CIS Controls all map back to
- Scales from a single manufacturing facility to a multi-site industrial enterprise
- No certification body — self-assessed or third-party assessed against the model
- Version 2.0 broadened scope beyond critical infrastructure to all organization types
- Applies to any commercial or industrial organization regardless of size
- The internationally recognized standard for an Information Security Management System (ISMS)
- Requires a formal risk assessment and treatment process, not just a technical checklist
- Certification is issued by accredited third-party bodies, unlike NIST CSF's self-assessment model
- Current version (ISO/IEC 27001:2022) added updated controls for cloud security and threat intelligence
- Often required by enterprise customers and international partners as a condition of doing business
- Provides a common security language for organizations operating across multiple countries
- Applies to any commercial or industrial organization seeking a certifiable, internationally recognized posture
- 18 prioritized, practical safeguards developed by the Center for Internet Security
- Organized into three Implementation Groups (IG1, IG2, IG3) scaled to organizational size and resources
- IG1 is specifically designed for smaller organizations with limited security staff
- Widely used as a practical starting point before pursuing a certifiable framework like ISO 27001
- Maps cleanly to NIST CSF and NIST SP 800-53 for organizations satisfying multiple frameworks
- Updated regularly to reflect current attacker techniques (currently version 8.1)
- Useful for right-sizing security investment by company size across commercial and industrial clients
California & Data Privacy
- California's consumer privacy law, enforced by the California Privacy Protection Agency (CPPA)
- Grants employees and customers rights to know, delete, and correct their personal information
- Applies based on revenue, data volume, or data-sales thresholds, not just company headcount
- Requires 'reasonable security procedures and practices' to protect personal information
- A breach of unencrypted personal information can trigger a private right of action with statutory damages
- A legal/privacy requirement distinct from, but complementary to, technical security frameworks
- Applies to any commercial or industrial business handling California employee or customer data
Situational & Adjacent
- Required for any organization that stores, processes, or transmits payment card data
- Currently on version 4.0.1, with new requirements like mandatory MFA now fully in effect
- Requires network segmentation between payment systems and the rest of the corporate network
- Compliance level and validation requirements scale with annual transaction volume
- Non-compliance can result in fines, increased transaction fees, or loss of card processing privileges
- Requires quarterly vulnerability scans by an Approved Scanning Vendor (ASV) for most merchants
- Applies to manufacturers and industrial operators with on-site retail, cafeteria, or B2B payment processing
Common questions from commercial & industrial operators.
IT/OT segmentation separates office information-technology systems from operational technology such as building automation, access control, and industrial monitoring systems, so a compromise on one side of the network can't spread to the other.
Standardization starts with a consistent, documented network design and configuration baseline applied to every location, so newer or smaller sites carry the same security posture as the primary facility rather than a weaker, ad hoc setup.
Yes, when the business handles sensitive data, connects multiple sites, or shares a network between IT and operational systems. Enterprise-grade platforms provide the segmentation, reliability, and centralized management that consumer-grade equipment can't support at that level of complexity.